Automatic
Activation Device Test Chamber
Automatic
parachute releases are sensitive to altitude pressure through an altitude
blocking mechanism. The principle action to be tested is the consistency of the
aneroid in releasing the mechanism at a predetermined altitude.
Normal test procedures involve evacuating air from the test chamber to simulate
an increase in altitude above the preset altitude of the release. At this point
an arming pin, which is blocking the parachute release firing mechanism, is
extracted and the release is armed. Pressurized air is bled back into the test
chamber to simulate a rate of decreasing altitude. When the simulated altitude
reaches the value for which the parachute release has been set the aneroid
releases the firing mechanism and the release operates.
The test chamber also has an adjustable "rate-of-descent" valve to
accurately check the FXC Model 12000 rate of descent requirement. It also checks
the altitude accuracy of the Model 2100, KAP-3, and Irvin Hitefinder releases.
Completely portable and weighs only 35 lbs.
Completely self-contained.
| Part No. |
Description |
| 711-07146 |
Tester,
Automatic Parachute Release (110V/60Hz) |
| 711-07146-1 |
Tester,
Automatic Parachute Release (220V/50Hz) |
|
|
|
Serving The World For Over 53 years!
|
|
Read and Follow all WARNINGS, WARRANTY and INSTRUCTIONS for products.
All Images, Text, and/or Pictures may not be used
without the expressed written consent of Para-Gear.
Prices and description are subject to change without notice.
|
 |
Order Phone Only: 1-87-PARA-GEAR or 1-800-323-0437
Phone: (847) 679-5905 Fax: (847) 679-8644
Contact Us: Click Here
3839 WEST OAKTON ST. SKOKIE, ILLINOIS 60076-3438 USA
© Copyright 1999-2013, Para-Gear Equipment Co. Inc.
All Rights Reserved.
|
|
|