Kestrel 1000 Features and Specifications:
Measurement
Response Time |
Units |
Operational
Range |
Resolution |
Accuracy (+/-) |
Specification
Range |
Wind Speed
1 second |
m/s |
0.4 to 60.0 m/s |
0.1 |
Larger of 3% of reading or
least significant digit |
0.4 to 40.0 m/s |
| ft/min |
59 to 11,948 ft/min |
1 |
59 to 7877 ft/min |
| km/h |
1.0 to 218.0 km/h |
0.1 |
1.0 to 144.0 km/h |
| mph |
0.8 to 135.0 mph |
1 |
0.8 to 89.0 mph |
| knots |
0.6 to 118.3 kt |
0.1 |
0.6 to 78.0 kt |
| Beaufort |
0 to 12 B |
0.1 |
0 to 12 B |
|
1 inch diameter impeller
with precision axle and sapphire bearings. Off-axis accuracy -1% @ 5º
off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours
use at 16 MPH / 7 m/s. Sustained operation above 60 MPH / 27 m/s will
wear impeller rapidly and may cause destruction of impeller.
Replacement impeller (NK PN-0801) may be field-installed without tools
(US Patent 5,783,753). |
|
Max/Avg Wind
Speed |
One-button clear and restart
of Max Wind Gust and Average Wind measurement. |
|
Display |
Reflective 3 1/2 digit LCD.
Digit height 0.36 in / 9 mm. |
|
Display Update |
1 second. |
|
Display
Backlight |
Aviation green
electroluminescent backlight. |
Operational
Temperature Range
(LCD and Batteries) |
The operational temperature
range of the liquid crystal display and batteries is 14° F to 131° F /
-10 °C to 55 °C. Beyond the limits of the operational temperature range,
the unit must be maintained within range and exposed for minimum time
necessary to take reading. |
|
Storage
Temperature |
-22 °F to 140 °F / -30 °C to
60 °C. |
|
Auto Shutdown |
After 45 minutes of no key
presses. |
|
Certifications |
CE certified. Individually
tested to NIST-traceable standards (written certificate of tests
available at additional charge). |
|
Batteries |
CR2032, one, included.
Average life, 300 hours of use, +/-depending on backlight use. |
|
Environmental |
Waterproof (IP67 standard).
Drop-tested (MIL.STD.810F; unit only. Substantial impact may damage
replaceable impeller.). |
|
Dimensions |
Unit 4.8 x 1.7 x 0.7 in /
122 x 42 x 18 mm. Case 4.8 x 1.9 x 1.1 in / 122 x 48 x 28 mm. |
|
Weight |
Unit 2.3 oz / 65 g. Case
1.3 oz / 37 g. |
Kestrel 3000 Features and Specifications:
Measurement
Response Time |
Units |
Operational Range |
Resolution |
Accuracy (+/-) |
Specification Range |
Wind Speed
1 second |
m/s |
0.4 to 60.0 m/s |
0.1 |
Larger of 3% of
reading or least significant digit |
0.4 to 40.0 m/s |
|
ft/min |
59 to 11,948 ft/min |
1 |
59 to 7877 ft/min |
|
km/h |
1.0 to 218.0 km/h |
0.1 |
1.0 to 144.0 km/h |
|
mph |
0.8 to 135.0 mph |
0.1 |
0.8 to 89.0 mph |
|
knots |
0.6 to 118.3 kt |
0.1 |
0.6 to 78.0 kt |
|
Beaufort |
0 to 12 B |
1 |
0 to 12 B |
|
1 inch diameter
impeller with precision axle and sapphire bearings. Off-axis accuracy
-1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after
100 hours use at 16 MPH / 7 m/s. Sustained operation above 60 MPH / 27
m/s will wear impeller rapidly and may cause destruction of impeller.
Replacement impeller (NK PN-0801) may be field-installed without tools
(US Patent 5,783,753). |
Temperature
1 second |
°F |
-49.0 to 257.0 °F |
0.1 |
1.8 °F |
-20.0 to 158.0 °F |
|
°C |
-45.0 to 125.0 °C |
0.1 |
1.0 °C |
-29.0 to 70.0 °C |
|
Measures air,
water and snow temperature. Thermally isolated, hermetically sealed,
precision thermistor mounted externally (US Patent 5,939,645).
Calibration drift negligible. |
Relative Humidity
1 minute |
%RH |
0.0 to 100.0 % |
0.1 |
3.0 %RH |
5.0 to 95.0 %
non-condensing |
|
Polymer
capacitive humidity sensor mounted in thin-walled chamber external to
case for rapid, accurate response (US Patent 6,257,074). (To achieve
stated relative humidity accuracy, unit must be permitted to equilibrate
to external temperature when exposed to large, rapid temperature changes
and must be kept out of direct sunlight.) Calibration drift +/- 2% over
24 months. Relative humidity may be recalibrated at factory or in field
using Kestrel Humidity Calibration Kit (NK PN-0802). |
Wind Chill
1 second |
°F |
0.7 to 135.0 MPH, -49.0 to
257.0 °F |
0.1 |
1.8 °F |
1.8 to 89.0 mph, -50.0 to
50.0 °F |
|
°C |
0.4 to 60.0 m/s, -45.0 to
125.0 °C |
0.1 |
1.0 °C |
0.4 to 40 m/s, -45.6 to 10.0
°C |
|
Calculated from
the primary measurements of wind speed and temperature. Utilizes the
NWS Wind Chill Temperature (WCT) Index, revised 2001, with wind speed
adjusted by a factor of 1.5 to yield equivalent results to wind speed
measured at 10 m above ground. (Specification temperature limits
established by WCT Tables.) |
Heat Index
1 minute |
°F |
0.0 to 100.0 %RH, -49.0 to
257.0 °F |
0.1 |
3.6 °F |
70.0 to 130.0 °F, 0 to 100%
RH |
|
°C |
0.0 to 100.0 %RH, -45.0 to
125.0 °C |
0.1 |
2.0 °C |
21.1 to 54.4 °C, 0 to 100
%RH |
|
Calculated from
the primary measurements of temperature and relative humidity. Utilizes
the NWS Heat Index (HI) tables. (Specification temperature limits
established by HI tables.) |
Dewpoint
1 minute |
°F |
0.0 to 100.0 %RH, -49.0 to
257.0 °F |
0.1 |
3.6 °F |
-20.0 to 158.0 °F, 20.0 to
95.0% RH |
|
°C |
0.0 to 100.0 %RH, -45.0 to
125.0 °C |
0.1 |
2.0 °C |
-29.0 to 70.0 °C, 20.0 to
95.0 %RH |
|
Calculated from
the primary measurements of temperature and relative humidity.
Temperature to which the air would need to be cooled at a constant
pressure to become saturated. |
|
Max/Avg Wind Speed |
One-button clear
and restart of Max Wind Gust and Average Wind measurement. |
|
Display |
Reflective 3 1/2 digit LCD.
Digit height 0.36 in / 9 mm. |
|
Display Update |
1 second. |
|
Display Backlight |
Aviation green
electroluminescent backlight. |
Operational Temperature Range
(LCD and Batteries) |
The operational
temperature range of the liquid crystal display and batteries is 14° F
to 131° F / -10 °C to 55 °C. Beyond the limits of the operational
temperature range, the unit must be maintained within range and exposed
for minimum time necessary to take reading. |
|
Storage Temperature |
-22 °F to 140 °F / -30 °C to
60 °C. |
|
Auto Shutdown |
After 45 minutes of no key
presses. |
|
Certifications |
CE certified. Individually
tested to NIST-traceable standards (written certificate of tests
available at additional charge). |
|
Batteries |
CR2032, one, included.
Average life, 300 hours of use, +/-depending on backlight use. |
|
Environmental |
Waterproof (IP67 standard).
Drop-tested (MIL.STD.810F; unit only. Substantial impact may damage
replaceable impeller.). |
|
Dimensions |
Unit 4.8 x 1.7 x 0.7 in /
122 x 42 x 18 mm. Case 4.8 x 1.9 x 1.1 in / 122 x 48 x 28 mm. |
|
Weight |
Unit 2.3 oz / 65 g. Case
1.3 oz / 37 g. |
Kestrel 3500 Features and Specifications:
Measurement
Response Time |
Units |
Operational Range |
Resolution |
Accuracy
(+/-) |
Specification Range |
Wind Speed
1 second |
m/s |
0.4 to 60.0 m/s |
0.1 |
Larger of 3% of
reading or least significant digit |
0.4 to 40.0 m/s |
|
ft/min |
59 to 11,948 ft/min |
1 |
59 to 7877 ft/min |
|
km/h |
1.0 to 218.0 km/h |
0.1 |
1.0 to 144.0 km/h |
|
mph |
0.8 to 135.0 mph |
1 |
0.8 to 89.0 mph |
|
knots |
0.6 to 118.3 kt |
0.1 |
0.6 to 78.0 kt |
|
Beaufort |
0 to 12 B |
0.1 |
0 to 12 B |
|
1 inch diameter
impeller with precision axle and sapphire bearings. Off-axis accuracy
-1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after
100 hours use at 16 MPH / 7 m/s. Sustained operation above 60 MPH / 27
m/s will wear impeller rapidly and may cause destruction of impeller.
Replacement impeller (NK PN-0801) may be field-installed without tools
(US Patent 5,783,753). |
Temperature
1 second |
°F |
-49.0 to 257.0 °F |
0.1 |
1.8 °F |
-20.0 to 158.0 °F |
|
°C |
-45.0 to 125.0 °C |
0.1 |
1.0 °C |
-29.0 to 70.0 °C |
|
Measures air,
water and snow temperature. Thermally isolated, hermetically sealed,
precision thermistor mounted externally (US Patent 5,939,645).
Calibration drift negligible. |
Relative Humidity
1 minute |
%RH |
0.0 to 100.0 % |
0.1 |
3.0 %RH |
5.0 to 95.0 %
non-condensing |
|
Polymer
capacitive humidity sensor mounted in thin-walled chamber external to
case for rapid, accurate response (US Patent 6,257,074). (To achieve
stated relative humidity accuracy, unit must be permitted to equilibrate
to external temperature when exposed to large, rapid temperature changes
and must be kept out of direct sunlight.) Calibration drift +/- 2% over
24 months. Relative humidity may be recalibrated at factory or in field
using Kestrel Humidity Calibration Kit (NK PN-0802). |
Pressure
1 second
(mb & PSI 4000 model only) |
inHg |
0.3 to 32.5 inHg |
0.01 |
0.05 inHg |
At 77.0 °F, 22.1 to 32.5
inHg |
|
hPa / mb |
10.0 to 1100.0 hPa / mb |
0.1 |
1.5 hPa / mb |
At 25.0 °C, 750 to 1100 hPa
/ mb |
|
PSI |
0.15 to 16.0 PSI |
0.01 |
0.02 PSI |
At 77.0 °F, 10.9 to 16.0 PSI |
|
Monolithic
silicon piezoresistive pressure sensor with second-order temperature
correction. Maximum error over temperature range 32 to 158 °F (0 to
70°C) , +/- 0.06 inHg / +/-2.0 hPa. Calibration drift typically -0.03
inHg / -1.0 hPa per year. Pressure sensor may be recalibrated at factory
or in field. |
Altitude
1 second |
ft |
-6000 to 30000 ft |
1 |
50 ft |
At 77.0 °F, <19,700 ft. Max
error +/- 98 ft |
|
m |
-2000 to 9000 m |
1 |
15 m |
At 25.0 °C, <6,000 m. Max
error +/- 30 m |
|
Temperature
compensated pressure (barometric) altimeter. |
Wind Chill
1 second |
°F |
0.7 to 135.0 MPH, -49.0 to 257.0 °F |
0.1 |
1.8 °F |
1.8 to 89.0 mph, -50.0 to
50.0 °F |
|
°C |
0.4 to 60.0 m/s, -45.0 to 125.0 °C |
0.1 |
1.0 °C |
0.4 to 40 m/s, -45.6 to 10.0
°C |
|
Calculated from
the primary measurements of wind speed and temperature. Utilizes the NWS
Wind Chill Temperature (WCT) Index, revised 2001, with wind speed
adjusted by a factor of 1.5 to yield equivalent results to wind speed
measured at 10 m above ground. (Specification temperature limits
established by WCT Tables.) |
Heat Index
1 minute |
°F |
0.0 to 100.0 %RH, -49.0 to 257.0 °F |
0.1 |
3.6 °F |
70.0 to 130.0 °F, 0 to 100%
RH |
|
°C |
0.0 to 100.0 %RH, -45.0 to 125.0 °C |
0.1 |
2.0 °C |
21.1 to 54.4 °C, 0 to 100
%RH |
|
Calculated from
the primary measurements of temperature and relative humidity. Utilizes
the NWS Heat Index (HI) tables. (Specification temperature limits
established by HI tables.) |
Dewpoint
1 minute |
°F |
0.0 to 100.0 %RH, -49.0 to 257.0 °F |
0.1 |
3.6 °F |
-20.0 to 158.0 °F, 20.0 to
95.0% RH |
|
°C |
0.0 to 100.0 %RH, -45.0 to 125.0 °C |
0.1 |
2.0 °C |
-29.0 to 70.0 °C, 20.0 to
95.0 %RH |
|
Calculated from
the primary measurements of temperature and relative humidity.
Temperature to which the air would need to be cooled at a constant
pressure to become saturated. |
|
Wet Bulb Temperature 1
minute |
°F |
-49.0 to 257.0 °F, 0.0 to 100.0
%RH, 8.86 to 32.48 inHg |
0.1 |
3.6 °F |
32.0 to 100.0 °F, 5.0 to
95.0% RH, 8.86 to 32.48 inHg, <19700 ft |
|
°C |
-45.0 to 125.0 °C, 0.0 to 100.0
%RH, 300.0 to 1100.0 hPa |
0.1 |
2.0 °C |
0.0 to 37.8 °C, 5.0 to 95.0
%RH, -2000.0 to 9000.0 hPa, <6000 m |
|
Calculated from
the primary measurements of temperature, relative humidity and pressure.
Temperature indicated by a wet bulb psychrometer. |
Max/Avg
Wind Speed |
One-button clear and restart
of Max Wind Gust and Average Wind measurement. |
|
Pressure Trend |
Continuously updating
three-hour barometric pressure trend indicator: rising rapidly, rising,
steady, falling, falling rapidly. |
|
Display |
Reflective 4 digit LCD.
Digit height 0.36 in / 9 mm. |
|
Display Update |
1 second. |
|
Display Backlight |
Aviation green
electroluminescent backlight. |
|
Clock / Calendar |
Real-time hours:minutes
clock. |
Operational Temperature Range
(LCD and Batteries) |
The operational temperature
range of the liquid crystal display and batteries is 14° F to 131° F /
-10 °C to 55 °C. Beyond the limits of the operational temperature range,
the unit must be maintained within range and exposed for minimum time
necessary to take reading. |
|
Storage Temperature |
-22 °F to 140 °F / -30 °C to
60 °C. |
|
Auto Shutdown |
After 45 minutes of no key
presses. |
|
Certifications |
CE certified. Individually
tested to NIST-traceable standards (written certificate of tests
available at additional charge). |
|
Batteries |
CR2032, one, included.
Average life, 300 hours of use, +/-depending on backlight use. |
|
Environmental |
Waterproof (IP67 standard).
Drop-tested (MIL.STD.810F; unit only. Substantial impact may damage
replaceable impeller.). |
|
Dimensions |
Unit 4.8 x 1.7 x 0.7 in /
122 x 42 x 18 mm. Case 4.8 x 1.9 x 1.1 in / 122 x 48 x 28 mm. |
|
Weight |
Unit 2.3 oz / 65 g. Case
1.3 oz / 37 g. |
Kestrel 4000 & 4000NV Features and
Specifications:
Measurement
Response Time |
Units |
Operational Range |
Resolution |
Accuracy (+/-) |
Specification Range |
Wind Speed
1 second |
m/s |
0.4 to 60.0 m/s |
0.1 |
Larger of 3% of
reading or least significant digit |
0.4 to 40.0 m/s |
|
ft/min |
59 to 11,948 ft/min |
1 |
59 to 7877 ft/min |
|
km/h |
1.0 to 218.0 km/h |
0.1 |
1.0 to 144.0 km/h |
|
mph |
0.8 to 135.0 mph |
1 |
0.8 to 89.0 mph |
|
knots |
0.6 to 118.3 kt |
0.1 |
0.6 to 78.0 kt |
|
Beaufort |
0 to 12 B |
0.1 |
0 to 12 B |
|
1 inch diameter
impeller with precision axle and sapphire bearings. Off-axis accuracy
-1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after
100 hours use at 16 MPH / 7 m/s. Sustained operation above 60 MPH / 27
m/s will wear impeller rapidly and may cause destruction of impeller.
Replacement impeller (NK PN-0801) may be field-installed without tools
(US Patent 5,783,753). |
Temperature
1 second |
°F |
-49.0 to 257.0 °F |
0.1 |
1.8 °F |
-20.0 to 158.0 °F |
|
°C |
-45.0 to 125.0 °C |
0.1 |
1.0 °C |
-29.0 to 70.0 °C |
|
Measures air,
water and snow temperature. Thermally isolated, hermetically sealed,
precision thermistor mounted externally (US Patent 5,939,645).
Calibration drift negligible. |
Relative Humidity
1 minute |
%RH |
0.0 to 100.0 % |
0.1 |
3.0 %RH |
5.0 to 95.0 %
non-condensing |
|
Polymer
capacitive humidity sensor mounted in thin-walled chamber external to
case for rapid, accurate response (US Patent 6,257,074). (To achieve
stated relative humidity accuracy, unit must be permitted to equilibrate
to external temperature when exposed to large, rapid temperature changes
and must be kept out of direct sunlight.) Calibration drift +/- 2% over
24 months. Relative humidity may be recalibrated at factory or in field
using Kestrel Humidity Calibration Kit (NK PN-0802). |
Pressure
1 second
(mb & PSI 4000 model only) |
inHg |
0.3 to 32.5 inHg |
0.01 |
0.05 inHg |
At 77.0 °F, 22.1 to 32.5
inHg |
|
hPa / mb |
10.0 to 1100.0 hPa / mb |
0.1 |
1.5 hPa / mb |
At 25.0 °C, 750 to 1100 hPa
/ mb |
|
PSI |
0.15 to 16.0 PSI |
0.01 |
0.02 PSI |
At 77.0 °F, 10.9 to 16.0 PSI |
|
Monolithic
silicon piezoresistive pressure sensor with second-order temperature
correction. Maximum error over temperature range 32 to 158 °F (0 to
70°C) , +/- 0.06 inHg / +/-2.0 hPa. Calibration drift typically -0.03
inHg / -1.0 hPa per year. Pressure sensor may be recalibrated at factory
or in field. |
Altitude
1 second |
ft |
-6000 to 30000 ft |
1 |
50 ft |
At 77.0 °F, <19,700 ft. Max
error +/- 98 ft |
|
m |
-2000 to 9000 m |
1 |
15 m |
At 25.0 °C, <6,000 m. Max
error +/- 30 m |
|
Temperature
compensated pressure (barometric) altimeter. |
Wind Chill
1 second |
°F |
0.7 to 135.0 MPH, -49.0 to
257.0 °F |
0.1 |
1.8 °F |
1.8 to 89.0 mph, -50.0 to
50.0 °F |
|
°C |
0.4 to 60.0 m/s, -45.0 to
125.0 °C |
0.1 |
1.0 °C |
0.4 to 40 m/s, -45.6 to 10.0
°C |
|
Calculated from
the primary measurements of wind speed and temperature. Utilizes the
NWS Wind Chill Temperature (WCT) Index, revised 2001, with wind speed
adjusted by a factor of 1.5 to yield equivalent results to wind speed
measured at 10 m above ground. (Specification temperature limits
established by WCT Tables.) |
Heat Index
1 minute |
°F |
0.0 to 100.0 %RH, -49.0 to
257.0 °F |
0.1 |
3.6 °F |
70.0 to 130.0 °F, 0 to 100%
RH |
|
°C |
0.0 to 100.0 %RH, -45.0 to
125.0 °C |
0.1 |
2.0 °C |
21.1 to 54.4 °C, 0 to 100
%RH |
|
Calculated from
the primary measurements of temperature and relative humidity. Utilizes
the NWS Heat Index (HI) tables. (Specification temperature limits
established by HI tables.) |
Dewpoint
1 minute |
°F |
0.0 to 100.0 %RH, -49.0 to
257.0 °F |
0.1 |
3.6 °F |
-20.0 to 158.0 °F, 20.0 to
95.0% RH |
|
°C |
0.0 to 100.0 %RH, -45.0 to
125.0 °C |
0.1 |
2.0 °C |
-29.0 to 70.0 °C, 20.0 to
95.0 %RH |
|
Calculated from
the primary measurements of temperature and relative humidity.
Temperature to which the air would need to be cooled at a constant
pressure to become saturated. |
|
Wet Bulb Temperature 1
minute |
°F |
-49.0 to 257.0 °F, 0.0 to
100.0 %RH, 8.86 to 32.48 inHg |
0.1 |
3.6 °F |
32.0 to 100.0 °F, 5.0 to
95.0% RH, 8.86 to 32.48 inHg, <19700 ft |
|
°C |
-45.0 to 125.0 °C, 0.0 to
100.0 %RH, 300.0 to 1100.0 hPa |
0.1 |
2.0 °C |
0.0 to 37.8 °C, 5.0 to 95.0
%RH, -2000.0 to 9000.0 hPa, <6000 m |
|
Calculated from
the primary measurements of temperature, relative humidity and pressure.
Temperature indicated by a wet bulb psychrometer. |
Density Altitude
1 second |
ft |
-49.0 to 257.0 °F, 0.0 to
100.0 % RH, 8.86 to 32.48 inHg |
1 |
246 |
32.0 to 100.0 °F, 5.0 to
95.0 %RH, 8.86 to 32.48 inHg, <19700 ft |
|
m |
-45.0 to 125.0 °C, 0.0 to
100.0 %RH, 300.0 to 1100.0 hPa |
1 |
75 |
0.0 - 37.8 °C, 5.0 to 95.0
%RH, -2000 to 9000 hPa, <6000 m |
|
Calculated from
the primary measurements of temperature, relative humidity and
pressure. Air density converted to equivalent sea level elevation at
the International Standard Atmosphere. |
Max/Avg Wind Speed (Air Velocity),
Crosswind, Headwind/Tailwind |
One-button clear and restart
of Max Wind Gust and Average Wind measurement. |
|
Data Storage / Display |
Minimum, maximum, average
and logged history stored and displayed for every measured value.
2000-point data logger with graphical display. Auto data storage;
interval settable from 2 seconds to 12 hours. Manual data capture. |
|
Data Upload |
Requires optional PC
interface (NK PN-0830) and provided software. RS-232 connection with USB
adapter available. |
|
Display |
Multifunction, multi-digit
programmable dot-matrix display. |
|
Display Update |
1 second. |
|
Display Backlight |
Choice of aviation green or
visible red electroluminescent backlight. Automatic or manual
activation. |
|
Clock / Calendar |
Real-time
hours:minutes:seconds clock, calendar, automatic leap-year adjustment. |
Operational Temperature Range
(LCD and Batteries) |
The operational temperature
range of the liquid crystal display and batteries is 14° F to 131° F /
-10 °C to 55 °C. Beyond the limits of the operational temperature range,
the unit must be maintained within range and exposed for minimum time
necessary to take reading. |
|
Storage Temperature |
-22 °F to 140 °F / -30 °C to
60 °C. |
|
Auto Shutdown |
User-selectable: 15 or 60
minutes with no key presses or disabled. |
|
Languages |
English, French, German,
Italian, Spanish. |
|
Certifications |
CE certified. Individually
tested to NIST-traceable standards (written certificate of tests
available at additional charge). |
|
Batteries |
AAA Alkaline, two, included.
Average life, 400 hours of use, +/-depending on backlight use. |
|
Environmental |
Waterproof (IP67 standard).
Drop-tested (MIL.STD.810F; unit only. Substantial impact may damage
replaceable impeller.). |
|
Dimensions |
Unit 5.0 x 1.8 x 1.1 in /
12.7 x 4.5 x 2.8 cm. |
|
Weight |
Unit 3.6 oz / 102 g. |
Kestrel 4500 & 4500NV Features and
Specifications:
Measurement
Response Time |
Units |
Operational Range |
Resolution |
Accuracy
(+/-) |
Specification Range |
Wind Speed
1 second |
m/s |
0.4 to 60.0 m/s |
0.1 |
Larger of 3% of
reading or least significant digit |
0.4 to 40.0 m/s |
|
ft/min |
59 to 11,948 ft/min |
1 |
59 to 7877 ft/min |
|
km/h |
1.0 to 218.0 km/h |
0.1 |
1.0 to 144.0 km/h |
|
mph |
0.8 to 135.0 mph |
1 |
0.8 to 89.0 mph |
|
knots |
0.6 to 118.3 kt |
0.1 |
0.6 to 78.0 kt |
|
Beaufort |
0 to 12 B |
0.1 |
0 to 12 B |
|
1 inch diameter
impeller with precision axle and sapphire bearings. Off-axis accuracy
-1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after
100 hours use at 16 MPH / 7 m/s. Sustained operation above 60 MPH / 27
m/s will wear impeller rapidly and may cause destruction of impeller.
Replacement impeller (NK PN-0801) may be field-installed without tools
(US Patent 5,783,753). |
Wind Direction / Forward Heading
1 second |
° |
360° |
1 |
5° |
0 to 360° |
|
Cardinal Points |
360° |
16 Points |
5° |
0 to 360° |
|
2-axis
solid-state magnetoresistive sensor mounted perpendicular to unit plane
to permit operation while measuring wind speed. Declination/variation
adjustable for True North readout. Accuracy of measurements dependent
upon unit's vertical position. Self-calibration routine eliminates
magnetic error from batteries or unit and must be run after every full
power-down (battery removal or change). |
Temperature
1 second |
°F |
-49.0 to 257.0 °F |
0.1 |
1.8 °F |
-20.0 to 158.0 °F |
|
°C |
-45.0 to 125.0 °C |
0.1 |
1.0 °C |
-29.0 to 70.0 °C |
|
Measures air,
water and snow temperature. Thermally isolated, hermetically sealed,
precision thermistor mounted externally (US Patent 5,939,645).
Calibration drift negligible. |
Relative Humidity
1 minute |
%RH |
0.0 to 100.0 % |
0.1 |
3.0 %RH |
5.0 to 95.0 %
non-condensing |
|
Polymer
capacitive humidity sensor mounted in thin-walled chamber external to
case for rapid, accurate response (US Patent 6,257,074). (To achieve
stated relative humidity accuracy, unit must be permitted to equilibrate
to external temperature when exposed to large, rapid temperature changes
and must be kept out of direct sunlight.) Calibration drift +/- 2% over
24 months. Relative humidity may be recalibrated at factory or in field
using Kestrel Humidity Calibration Kit (NK PN-0802). |
Pressure
1 second
(mb & PSI 4000 model only) |
inHg |
0.3 to 32.5 inHg |
0.01 |
0.05 inHg |
At 77.0 °F, 22.1 to 32.5
inHg |
|
hPa / mb |
10.0 to 1100.0 hPa / mb |
0.1 |
1.5 hPa / mb |
At 25.0 °C, 750 to 1100 hPa
/ mb |
|
PSI |
0.15 to 16.0 PSI |
0.01 |
0.02 PSI |
At 77.0 °F, 10.9 to 16.0 PSI |
|
Monolithic
silicon piezoresistive pressure sensor with second-order temperature
correction. Maximum error over temperature range 32 to 158 °F (0 to
70°C) , +/- 0.06 inHg / +/-2.0 hPa. Calibration drift typically -0.03
inHg / -1.0 hPa per year. Pressure sensor may be recalibrated at factory
or in field. |
Altitude
1 second |
ft |
-6000 to 30000 ft |
1 |
50 ft |
At 77.0 °F, <19,700 ft. Max
error +/- 98 ft |
|
m |
-2000 to 9000 m |
1 |
15 m |
At 25.0 °C, <6,000 m. Max
error +/- 30 m |
|
Temperature
compensated pressure (barometric) altimeter. |
Crosswind
Headwind, Tailwind
1 second |
mph |
0.8 to 135.0 mph |
1 |
5% |
8.5 to 89.0 mph |
|
ft/min |
59 to 11,880 ft/min |
1 |
5% |
750 to 7832 ft/min |
|
km/h |
1.0 to 217.3 km/h |
0.1 |
5% |
13.7 to 143.2 km/h |
|
m/s |
0.4 to 60.0 m/s |
0.1 |
5% |
3.8 to 40.0 m/s |
|
knots |
0.6 to 117.3 kt |
0.1 |
5% |
7.4 to 77.0 kt |
|
Calculated from
the primary measurements of wind speed, wind direction and target
heading. Auto-switching headwind/tailwind indication. Ranges expressed
refer to primarywind speed. |
Wind Chill
1 second |
°F |
0.7 to 135.0 MPH, -49.0 to
257.0 °F |
0.1 |
1.8 °F |
1.8 to 89.0 mph, -50.0 to
50.0 °F |
|
°C |
0.4 to 60.0 m/s, -45.0 to
125.0 °C |
0.1 |
1.0 °C |
0.4 to 40 m/s, -45.6 to 10.0
°C |
|
Calculated from
the primary measurements of wind speed and temperature. Utilizes the
NWS Wind Chill Temperature (WCT) Index, revised 2001, with wind speed
adjusted by a factor of 1.5 to yield equivalent results to wind speed
measured at 10 m above ground. (Specification temperature limits
established by WCT Tables.) |
Heat Index
1 minute |
°F |
0.0 to 100.0 %RH, -49.0 to
257.0 °F |
0.1 |
3.6 °F |
70.0 to 130.0 °F, 0 to 100%
RH |
|
°C |
0.0 to 100.0 %RH, -45.0 to
125.0 °C |
0.1 |
2.0 °C |
21.1 to 54.4 °C, 0 to 100
%RH |
|
Calculated from
the primary measurements of temperature and relative humidity. Utilizes
the NWS Heat Index (HI) tables. (Specification temperature limits
established by HI tables.) |
Dewpoint
1 minute |
°F |
0.0 to 100.0 %RH, -49.0 to
257.0 °F |
0.1 |
3.6 °F |
-20.0 to 158.0 °F, 20.0 to
95.0% RH |
|
°C |
0.0 to 100.0 %RH, -45.0 to
125.0 °C |
0.1 |
2.0 °C |
-29.0 to 70.0 °C, 20.0 to
95.0 %RH |
|
Calculated from
the primary measurements of temperature and relative humidity.
Temperature to which the air would need to be cooled at a constant
pressure to become saturated. |
Wet Bulb Temperature
1 minute |
°F |
-49.0 to 257.0 °F, 0.0 to
100.0 %RH, 8.86 to 32.48 inHg |
0.1 |
3.6 °F |
32.0 to 100.0 °F, 5.0 to
95.0% RH, 8.86 to 32.48 inHg, <19700 ft |
|
°C |
-45.0 to 125.0 °C, 0.0 to
100.0 %RH, 300.0 to 1100.0 hPa |
0.1 |
2.0 °C |
0.0 to 37.8 °C, 5.0 to 95.0
%RH, -2000.0 to 9000.0 hPa, <6000 m |
|
Calculated from
the primary measurements of temperature, relative humidity and pressure.
Temperature indicated by a wet bulb psychrometer. |
Density Altitude
1 second |
ft |
-49.0 to 257.0 °F, 0.0 to
100.0 % RH, 8.86 to 32.48 inHg |
1 |
246 |
32.0 to 100.0 °F, 5.0 to
95.0 %RH, 8.86 to 32.48 inHg, <19700 ft |
|
m |
-45.0 to 125.0 °C, 0.0 to
100.0 %RH, 300.0 to 1100.0 hPa |
1 |
75 |
0.0 - 37.8 °C, 5.0 to 95.0
%RH, -2000 to 9000 hPa, <6000 m |
|
Calculated from
the primary measurements of temperature, relative humidity and
pressure. Air density converted to equivalent sea level elevation at
the International Standard Atmosphere. |
Max/Avg Wind Speed (Air Velocity),
Crosswind, Headwind/Tailwind |
One-button clear and restart
of Max Wind Gust and Average Wind measurement. |
|
Data Storage / Display |
Minimum, maximum, average
and logged history stored and displayed for every measured value.
1400-point data logger with graphical display. Auto data storage;
interval settable from 2 seconds to 12 hours. Manual data capture. |
|
Data Upload |
Requires optional PC
interface (NK PN-0830) and provided software. RS-232 connection with USB
adapter available. |
|
Display |
Multifunction, multi-digit
programmable dot-matrix display. |
|
Display Update |
1 second. |
|
Display Backlight |
Choice of aviation green or
visible red electroluminescent backlight. Automatic or manual
activation. |
|
Clock / Calendar |
Real-time
hours:minutes:seconds clock, calendar, automatic leap-year adjustment. |
Operational Temperature Range
(LCD and Batteries) |
The operational temperature
range of the liquid crystal display and batteries is 14° F to 131° F /
-10 °C to 55 °C. Beyond the limits of the operational temperature range,
the unit must be maintained within range and exposed for minimum time
necessary to take reading. |
|
Storage Temperature |
-22 °F to 140 °F / -30 °C to
60 °C. |
|
Auto Shutdown |
User-selectable: 15 or 60
minutes with no key presses or disabled. |
|
Languages |
English, French, German,
Italian, Spanish. |
|
Certifications |
CE certified. Individually
tested to NIST-traceable standards (written certificate of tests
available at additional charge). |
|
Batteries |
AAA Alkaline, two, included.
Average life, 400 hours of use, +/-depending on backlight use. |
|
Environmental |
Waterproof (IP67 standard).
Drop-tested (MIL.STD.810F; unit only. Substantial impact may damage
replaceable impeller.). |
|
Dimensions |
Unit 5.0 x 1.8 x 1.1 in /
12.7 x 4.5 x 2.8 cm. |
|
Weight |
Unit 3.6 oz / 102 g. |
|
|
Serving The World For Over 53 years!
|
|
Read and Follow all WARNINGS, WARRANTY and INSTRUCTIONS for products.
All Images, Text, and/or Pictures may not be used
without the expressed written consent of Para-Gear.